OPERATING TEMPERATURE RANGE From -55°C to +105°C
INSULATION RESISTANCE
When measured at test temperature and rated voltage for a minimum of two (2) minutes, the insulation resistance equals or exceeds the following values
| Temperature |
25°C |
85°C |
105°C |
| Megohms x Microfarads |
50,000 |
5,000 |
150 |
| Insulation resistance in megohms need not exceed: |
200,000 |
20,000 |
2,000 |
DISSIPATION FACTOR
When measured at the frequency specified for capacitance measurement, the dissipation factor will not exceed 0.1%.
|
CAPACITANCE CHANGE
Capacitance change versus temperature for these capacitors shall not exceed the following:
| Temperature Degrees C. |
-55 |
+25 |
+105 |
| Percent Change |
+2.0 |
0 |
-4.0 |
| Typical |
+1.6 |
0 |
-2.2 |
DIELECTRIC STRENGTH
Capacitors withstand a DC potential of 1.5 x rated voltage for one (1) minute without damage or breakdown. Test voltage is applied and discharged through a minimum resistance of 100 OHMS per volt.
CAPACITANCE TOLERANCE
Standard tolerance is ± 10%. Tolerances of ±5%, and ±20% also available.
NOTE: Capacitance is measured at 25°C, and at a frequency of 1KHZ for all values.
|